Prima Cable Indo adalah perusahaan yang bergerak dibidang usaha kabel manufacturing yang awalnya telah dirintis oleh Putra Omentraco. Saat ini PT Prima Cable Indo telah menjadi salah satu produsen konduktor dan kabel yang memenuhi standar baik nasional maupun internasional serta kabel spesial berdasaarkan permintaan konsumen. 
 
PT. Prima Cable Indo terus berinovasi terhadap produknya dengan dukungan penambahan fasilitas mesin, alat uji dan SDM untuk memenuhi visi dan misi perusahaan.   

 

BARE CONDUCTOR

Versi ramah cetakPDF version

Cable BCC is a cable conductor. Many of the common terms in the BC cable are one of the "open wires", because these cables are seen only conductors without any protective jackets. BC cable is divided into 2 types, namely Aluminum or Copper cable.

Copper BC cable is called BCC (Bare Copper Conductor and Aluminum BC cable is called AAC (All Aluminum Conductor (AAC) .Each of BC cable has the development of each cable type for better like BCC has BCC-Hard type, or AAC has AAAC (All Aluminum Alloy Conductor) as described above AAAC or ACAR Usage = Channels above ground and grounding.

OHSAS 18001:2007 Kesehatan dan Keselamatan

Versi ramah cetakPDF version
Standar OHSAS 18001 menyediakan elemen-elemen sistem manajemen keselamatan yang efektif yang dapat diintegrasikan dengan sistem manajemen lain dan membantu organisasi mencapai kinerja kesehatan dan keselamatan kerja yang lebih baik dan tujuan ekonomi. PT. Prima Cable Indo telah mendapatkan sertifikasi OHSAS 18001:2007  pada 28 November 2017
 
SILAHKAN UNDUH  TANDA BUKTI SERTIFIKASI
 
 
 
 

HEALTH & SAFETY ENVIRONMENT

Versi ramah cetakPDF version

Occupational Safety and Health Team Prima Cable Indo (HSE) is actively covering this scope, striving to ensure sustainable cable and cable usage in Indonesia. The commitment provided by Prima Cable Indo is also disclosed through Environmental Security Certification

PRODUCT

Versi ramah cetakPDF version

About Product

Cu/PVC/PVC 450 / 750 V (NYM)

Versi ramah cetakPDF version
Material Inti: 
Cu
CU/PVC/PVC 
 
Application :
Power cable: indoors, cable trunking, outdoors and buried in the ground for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely.
 
Special Features on Request :
 
Fire resistance
Oil resistance
UV resistance
Flame Retardant Cat A,B,C
Flame Retardant non-category
Heat resistance
Anti-termite
Anti-rodent
Low smoke zero halogen
Note: Conductor shape
 
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 sqmm supplied in non-compacted circular circular stranded (rm) conductor shape
25-500 sqmm supplied in non-compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
11.5 – 10 sqmm supplied in coil @ 100 meters
16 – 300 sqmm supplied in wooden drum @ 1000 meters
400 – 500 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%
Unduhan : 
PDF icon NYM.v1.pdf (517.86 KB)

Cu/XLPE/CTS/PVC 0.6/1 (1.2) kV (N2XSY)

Versi ramah cetakPDF version
Material Inti: 
Cu
N2XSY ( Cu / XLPE / CTS / PVC )
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed)
Standard Specification : IEC 60502 – 2
 
 
Application :
Indoors, cable trunking, outdoors and in ground; For power stations, industry and switchgear.
 
Special Features on Request :
 
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Note : Conductor Shape
35 – 300 sqmm supplied in compacted circular stranded (cm) conductor shape
 
Standard Packing :
 
35 – 95 sqmm supplied in wooden drum @ 1000 meters
120 – 300 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%

GSW

Versi ramah cetakPDF version
Material Inti: 
Al
Detil Deskripsi produk
Konduktor: Galvanized Steel Wire nama sandi: GSW
Tunggal kawat Diameter: 1,24-2,50 Kekuatan tarik: 1290mpa ~ 1620mpa
Aplikasi: Inti dari ACSR
 

 

Galvanized Steel Wire Bare Conductor

 

 

Kawat produk baja galvanis (GSW) digunakan untuk kabel dari ACSR (Aluminium Conductor Steel Reinforced) konduktor

 

Visi dan Misi

Bahasa Indonesia
Vision and mission

Vision

Putting forward quality in every real step, for optimal achievement.
 

Mission

Meet consumer expectations in terms of product quality, service and satisfaction.

Able to compete, both in domestic and international market

Establish a good and healthy cooperation with relations or partners to meet the growing market needs

It is the obligation of the whole range of companies from managers to executives to understand, implement and develop consistently quality standards in all divisions in order to achieve the set targets.

ISO 14001: 2015 Environmental Management

English
 
ISO 14001 defines the criteria for EMS. It does not state requirements for environmental performance but rather maps the frameworks that companies or organizations can follow to prepare an effective EMS. It can be used by any organization that wants to improve resource efficiency, reduce waste, and reduce costs. Using ISO 14001 can provide assurance to company management and employees and external stakeholders that environmental impacts are measured and improved. [6] ISO 14001 can also be integrated with other management functions and assist companies in meeting their environmental and economic goals.
 
 
ISO 14001, like other ISO 14000 standards, is voluntary [11], with the primary objective of assisting companies in continuously improving their environmental performance and complying with applicable law. The organization sets its own performance targets and measures, and the standard highlights what the organization needs to do to meet those objectives, and to monitor and measure the situation. [11] The standard does not focus on environmental performance measures and targets, but also organizations. They can be applied at various levels in business, from the organizational level to the product and service levels.
 
ISO 14001 is known as a generic management system standard, which means it is relevant to organizations that seek to improve and manage resources more effectively. These include:
 
one site to a large multinational company
companies are at high risk to low-risk service organizations
manufacturing, process and service industries, including local governments
all industrial sectors, including the public and private sectors
original equipment manufacturers and their suppliers
All standards are reviewed regularly by ISO to ensure they continue to meet market requirements. The current version is ISO 14001: 2015, and certification organizations are given a three-year transition period to adjust their environmental management system to new editions of this standard. The new version of ISO 14001 focuses on improving environmental performance rather than improving the management system itself. [12] It also includes several new updates all aimed at making environmental management more comprehensive and relevant to the supply chain. One major update asks the organization to consider its environmental impact during the entire life cycle, although there is no requirement to actually complete the life cycle analysis. In addition, top management commitments and compliance assessment methods have also been strengthened. Other significant changes related to ISO 14001 with the general management system structure, introduced in 2015, called the High Level Structure. Both ISO 9001 and 14001 use the same structure, making implementation and auditing more uniform. The new standard also requires certificate holders to determine risks and opportunities and how to overcome them

Cu/PVC - f 450/750 V (NYAF)

Versi ramah cetakPDF version
Material Inti: 
Cu

CU/PVC   (NYAF )                        
Copper Conductor Flexible, PVC Insulated                        
                        
Building Cable        
450/750Volt        
                        
Standard Specification  :        
SPLN 42 -3:  1992        
SNI 04 - 6629.3  2006        
                        
Application :        
Permanent instalation in conduit and cable conection in distribution cabinets or Exposed wiring in dry location        
                        
Conductor Shape :        
1.5  - 240 sqmm supplied in bunching wire        
                        
Identification of Core :        
Green - Yellow or Red or Light Blue or Yellow or Black or Brown or Gray        
                        
Standard Packing :        
1.5  -  50  sqmm Coil system        
70  -  240 sqmm wooden drum/haspel        
                        
Special Feature on Request  (B)

 
Tanggal Kegiatan : 
Rabu, Februari 15, 2017
Unduhan : 
PDF icon NYA-NYAF.v1.pdf (1.01 MB)

Audit SMK3 Sistem Manajemen Keselamatan dan Kesehatan Kerja Memenuhi Syarat

Versi ramah cetakPDF version

SMK3 diwajibkan  bagi perusahaan yang mempunyai tingkat potensi bahaya tinggi. Untuk itu perusahaan diwajibkan menyusun Rencana K3, dalam menyusun rencana K3 tersebut,  pengusaha  melibatkan Ahli K3, Panitya Pembina Keselamatan dan Kesehatan Kerja(P2K3), Wakil Pekerja dan Pihak Lain yang terkait Sertifikat Audit SMK3 Sistem Manajemen Keselamatan dan Kesehatan Kerja

 

PT. Prima Cable Indo juga sudah bersertifikat sesuai aturan dengan yang telah dijalankan

Vision and Mission

Versi ramah cetakPDF version
VISION AND MISSION
 
Vision:
Being a leading cable manufacturer in Indonesia
 
 
Mission:
1) Contribution in reliable power and telecommunication construction.
2) Building awareness of personnel in terms of quality, safety and health and environmental protection.
3) Establish cooperation and partnership with the principle of win-win solution with the stakeholders.
4) Implementation of the principle of continuous improvement in the competence of human resources, science and technology per-cable-an, and reliability of infrastructure used.

AAC (1350)

Versi ramah cetakPDF version
Sertifikasi: 
ASTM B 215 Part 1 : 1970
ASTM B 231 : 2004
IEC C 61089 : 1991
Material Inti: 
Al
AAC (1350)
All Aluminum Conductor
 
Aplikasi :
Konduktor pada ruang terbuka
 
Klasifikasi :
Bare Conductor
 
Jangkauan Ukuran :
35 - 1200 mm2
 
Konstruksi :
Alumunium Stranded

Standard Kemasa
Haspel terbuat dari kayu atau Haspel Kombinasi Kayu dan Besi

Harap Download Brosur dibawah ini atau hub marketing sales kami melalui FORM KONTAK

Unduhan : 
PDF icon AAC.v1.pdf (724.77 KB)

Cu/PVC/PVC - f 450 /750 V (NYMHY)

Versi ramah cetakPDF version
Material Inti: 
Cu
CU / PVC / PVC (NYMHY)
KAWAT BANGUNAN
 
Spesifikasi Standar:
SPLN 42-6-2: 1991
SNI 04-6629.5-2006
 
Aplikasi:
Kabel listrik: di dalam ruangan, kabel trunking, di luar ruangan dan dikubur di dalam tanah untuk pembangkit listrik, industri dan switch gear serta untuk jaringan suplai perkotaan.
 
 
1,5 - 10 sqmm dipasok dalam bentuk gelang bulat bulat padat (re) atau tidak dipadatkan bulat bulat (rm) berbentuk konduktor
16 sqmm dipasangkan dalam bentuk konduktor bulat bundar (rm) berbentuk lingkaran yang tidak dipadatkan
25-500 sqmm yang dipasok dalam bentuk bulat bulat (rm) atau bentuk pita bulat melingkar yang tidak padat dan dipadatkan (cm)
Kemasan standar:
 
11,5 - 10 meter persegi yang disediakan dalam gulungan @ 100 meter
16 - 300 meter persegi yang disediakan dalam drum kayu @ 1000 meter
400 - 500 sqmm yang disediakan dalam drum kayu dengan panjang yang tersedia
Toleransi Panjang per drum ± 2%
Unduhan : 
PDF icon NYMHY.v1.pdf (679.53 KB)

Statistik

Versi ramah cetakPDF version



T-ACSR

Versi ramah cetakPDF version
Material Inti: 
Al

Welcome to Primacableindo

English
PT. PrimaCableIndo established since 1994 and engaged in electricity. We produce various types of cables for industrial, residential and apartement and office buildings.
Our office is located in Central Jakarta area and we have 2 factory location in Jati Uwung and Bandung. Until now Prima Cable Indo manufactures two brands of cables namely PUTERA and PRICA.

SMK 3 Audit Safety and Health Management System Eligible

English
SMK 3 is required for companies, employing more than 100 people and has high potential hazards. Therefore, the company is required to prepare the OSH Plan, in preparing the OSH plan, the entrepreneur shall involve the Occupational Safety and Health Expert, Working Committee on Occupational Safety and Health (P2K3), Workers Representative and Other Related Parties
Certificate of Audit of SMK3 Occupational Safety and Health Management System
 
Valid: December 11, 2017
 

Sejarah Perusahaan

Versi ramah cetakPDF version

PT. Prima Cable Indo adalah perusahaan Manufaktur konduktor, kabel listrik dan telekomunikasi yang didirikan pada tahun . perusahaan yang awalnya bernama Putra Ometraco Electric ini menjadi salah satu produsen kabel dengan teknologi dan kualitas yang baik. Pada tahun 2002 berubah nama menjadi Prima Cable Indo yang berdomisili di Tangerang dengan merekrut tenaga-tenaga ahli yang berpengalaman dan berdedikasi penuh dibidangnya. Hal ini bisa dilihat dari pengalaman pekerjaan yang telah diselesaikan.
PT. Prima Cable Indo merupakan perusahaan yang bergerak dibidang pabrikan kabel tegangan rendah dan menengah dengan merek dagang PUTERA KABEL dan PRICA KABEL yang berstandar SPLN dan SNI. SAat ini kami terus berinvestasi untuk pengembangan usaha, mengadakan mesin - mesin baru dan perekrutan sumber daya manusia, guna meningkatkan kapasitas dan kualitas produksi menjadi lebih baik. 

Kontrol Kualitas

Versi ramah cetakPDF version

Kami terus berkomitmen untuk menjaga, mendukung, memeriksa dan memperbaiki dan memelihara sistem mutu kami untuk memenuhi spesifikasi industri dan standar kualitas yang diminta oleh pelanggan.

Sejak awal, sistem manajemen mutu telah didokumentasikan dan diimplementasikan dan dipraktekkan pada setiap tahap operasi pabrik.

Fokus utamanya adalah pada pengendalian proses melalui sistem penjaminan mutu yang dinamis, pengembangan produk dan perbaikan terus-menerus dalam setiap proses manufaktur

Kualitas tetap dan akan terus menjadi prioritas utama kami di PT. Prima Cable Indo.

Standarisasi 1

Versi ramah cetakPDF version

Tentang Standarization

AAAC (6201)

Versi ramah cetakPDF version
Sertifikasi: 
ASTM B 215 Part 1 : 1970
Material Inti: 
Al

AAAC (6201)
All Aluminum Alloy Conductor

Standar Spesifikasi :

ASTM B399:2004

BS 3242: 1970

Tipe Konduktor :
AAAC 6201

Aplikasi:
Digunakan untuk konduktor  jalur distribusi pada ruang terbuka

Jangkauan Ukuran :
16 - 1000 mm2

Bentuk Kondutor :
Stranded Wire

Identifikasi Inti
Konduktor inti tunggal dengan arah lapisan terluar Right(Z)

Standard Kemasan
Hasfel terbuat dari kayu atau haspel Rangka Kayu dan Besi

Dapat dipesan dengan fitur yang bisa disesuaikan

Harap Download Brosur dibawah ini atau hub marketing sales kami melalui FORM KONTAK

Unduhan : 
PDF icon AAAC.v1.pdf (1.08 MB)

Cu/PVC/PVC - f 450 /750 V (NYMHY)

Versi ramah cetakPDF version
Material Inti: 
Cu
CU/PVC/PVC (NYMHY)
BUILDING WIRE
 
Standard Specification : 
SPLN 42-6-2 : 1991 
SNI 04-6629.5-2006
 
Application :
Power cable: indoors, cable trunking, outdoors and buried in the ground for power stations, industry and switchgear as well as for urban supply networks.
 
 
1.5 – 10 sqmm supplied in solid  round ankel (re) or non compacted circular stranded round multi (rm) conductor shape
16 sqmm supplied in non-compacted circular circular stranded round multi (rm) conductor shape
25-500 sqmm supplied in non-compacted circular stranded round multi(rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
11.5 – 10 sqmm supplied in coil @ 100 meters
16 – 300 sqmm supplied in wooden drum @ 1000 meters
400 – 500 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%
Unduhan : 
PDF icon NYMHY.v1.pdf (679.53 KB)

Al/PVC 450 / 750 V (NAYA)

Versi ramah cetakPDF version
Material Inti: 
Al
Al / PVC 450/750 V (NAYA)
(Konduktor Aluminium, PVC Terisolasi)
Spesifikasi Standar: SPLN 42-1, SNI 04-6629.3, IEC 60502-1
 
 
Aplikasi:
Untuk kawat bangunan dipasang di saluran di lokasi kering dan antar kabel di panel switchboard dan kontrol.
 
Fitur Khusus Permintaan:
 
Tahan api
Perlawanan Minyak
Flame Retardant Cat. A, B, C
Flame Retardant Non Kategori
Catatan: Bentuk konduktor
 
1,5 - 16 sqmm disediakan dalam koil @ 100 meter
25 - 400 sqmm dipasok di drum kayu @ 1000 meter
Panjang Toleransi per drum ± 2%
Packing Standar:
 
1,5 - 10 sqmm dipasok dalam bentuk konduktor padat (re) atau non compacted circular stranded (rm)
16 - 400 sqmm disediakan dalam bentuk konduktor sirkuler terdampar (rm) yang tidak dipadatkan

T-ACSR/AS

Versi ramah cetakPDF version
Material Inti: 
Al

Selamat Datang di PT. Prima Cable Indo

Bahasa Indonesia
PT. PrimaCableIndo berdiri sejak tahun 1994 dan bergerak di bidang kelistrikan. Kami memproduksi berbagai jenis kabel untuk industri, perumahan dan apartement dan gedung perkantoran.
Kantor kami berlokasi di wilayah Jakarta Pusat dan kami memiliki 2 lokasi pabrik di Jati Uwung dan Bandung. Hingga saat ini Prima Cable Indo memproduksi dua merek kabel yaitu PUTERA dan PRICA.

LMK Certification

English

STANDAR TINGGI

Versi ramah cetakPDF version

Prima Cable Indo memproduksi kabel dengan menggunakan kawat paduan tembaga berkekuatan tinggi yang dikembangkan secara independen. Sambil mempertahankan konduktivitas yang tinggi, kawat ini memiliki kekuatan tarik dan kekuatan lentur berulang dua kali lipat dari kawat paduan umum dan daya tahan lenturnya yang superior memastikan umur yang panjang. Prima Cable Indo mampu menyesuaikan proposal untuk robot industri, serta berbagai skenario di mana kabel fleksibel dibutuhkan.

Audit (SMK3) Management System Occupational Safety and Health Compliance

Versi ramah cetakPDF version
SMK3 is required for companies, employing more than 100 people and has high potential hazards. Therefore, the company is required to prepare the OSH Plan, in preparing the OSH plan, the entrepreneur shall involve the Occupational Health and Safety Expert, Working Committee for Occupational Safety and Health (P2K3), Workers Representative and other Related Parties. Primacableindo has qualified for SMK3 

Certificate of Audit of SMK3 Occupational Safety and Health Management System: Valid: December 11, 2017

AAAC (6201)

Versi ramah cetakPDF version
Sertifikasi: 
ASTM B 215 Part 1 : 1970
Material Inti: 
Al
AAAC (6201)
All Aluminum Alloy Conductor
 
Standard Specifications:
 
ASTM B399: 2004
 
BS 3242: 1970
 
 
Conductor Type:
AAAC 6201
 
Application:
Used for conductors of distribution channels in open spaces
 
Reach Size:
16 - 1000 mm2
 
Condutor Form:
Stranded Wire
 
Core Identification
Single core conductor with outer layer direction Right (Z)
 
Standard Packaging
Hasfel made of wood or haspel Wood and Iron Frame
 
Can be ordered with customizable features
 
Please Download Brochure below or our marketing sales hub through CONTACT FORM
Unduhan : 
PDF icon AAAC.v1.pdf (1.08 MB)

Cu/PVC/PVC - f 450 / 750 V (NYYHY)

Versi ramah cetakPDF version
Material Inti: 
Cu
CU/PVC/PVC (NYYHY)
CONTROL CABLE FLEXIBLE WIRE
 
Standard Specification : 
SNI 04-6629.7-2006
IEC 60227-6:2001
 
Application :
Power cable: indoors, cable trunking, outdoors and buried in the ground for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely.
 
Special Features on Request :
 
Fire resistance
Oil resistance
UV resistance
Flame Retardant Cat A,B,C
Flame Retardant non-category
Heat resistance
Anti-termite
Anti-rodent
Low smoke zero halogen
Note: Conductor shape
 
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 sqmm supplied in non-compacted circular circular stranded (rm) conductor shape
25-500 sqmm supplied in non-compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
11.5 – 10 sqmm supplied in coil @ 100 meters
16 – 300 sqmm supplied in wooden drum @ 1000 meters
400 – 500 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%
Unduhan : 
PDF icon NYYHY.v1.pdf (2 MB)

Al/PVC 450 / 750 V (NAYA)

Versi ramah cetakPDF version
Material Inti: 
Al

Al/PVC   450 / 750 V (NAYA)
(Aluminium Conductor, PVC Insulated)
Standard Specification : SPLN 42-1, SNI 04-6629.3, IEC 60502-1

Application :
For building wire installed in conduit in dry location and inter wiring in switchboard and control panel.

Special Features on Request :

Fire Resistance
Oil Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Note: Conductor shape

1.5 – 16 sqmm supplied in coil @ 100 meters
25 – 400 sqmm supplied in wooden drum @ 1000 meters
Length Tolerance per drum ± 2%
Standard Packing :

1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 – 400 sqmm supplied in non compacted circular stranded (rm) conductor shape

HTLS (High Thermal Low Sag)

Versi ramah cetakPDF version
Material Inti: 
Al

ACSR

Versi ramah cetakPDF version
Material Inti: 
Al

Visi dan Misi

Bahasa Indonesia
Visi dan Misi
 
Visi
 
Menempatkan kualitas ke depan dalam setiap langkah nyata, untuk pencapaian yang optimal.
 
 
Misi
 
Memenuhi harapan konsumen dalam hal kualitas produk, pelayanan dan kepuasan.
 
Mampu bersaing, baik di pasar domestik maupun internasional
 
Menjalin kerja sama yang baik dan sehat dengan relasi atau mitra untuk memenuhi kebutuhan pasar yang terus berkembang
 
Ini adalah kewajiban seluruh jajaran perusahaan mulai dari manajer hingga eksekutif untuk memahami, menerapkan dan mengembangkan standar kualitas yang konsisten di semua divisi untuk mencapai target yang ditetapkan.

STANDARD OF PRODUCT

English

 

 

Code Name Note
SPLN Standard Perusahaan Listrik Negara
SNI Standard Nasional Indonesia
IEC International Electrotechnical Commission
VDE Verband des Deutscher Elektrotechniker
JIS Japanese Industrial Standard
BS British Standard
ICEA Insulated Cables Engineers Association
NEMA National Electrical Manufacturer Association
AS Australian Standard
ASTM American Society for Testing and Material
Other Specifications are available upon request

 

 

KESELAMATAN & KEAMANAN

Versi ramah cetakPDF version

Tim Keselamatan dan Kesehatan Kerja Prima Cable Indo (HSE) secara aktif meliput lingkup ini, berusaha memastikan penggunaan kabel dan kabel yang berkelanjutan di Indonesia. Komitmen yang diberikan oleh Prima Cable Indo juga diungkapkan melalui Sertifikasi Keamanan Lingkungan

AAAC-S

Versi ramah cetakPDF version
Sertifikasi: 
SPLN 41 - 10
Material Inti: 
Al
Core Materials:
Al
 
AAAC-S
 
All Aluminum Alloy Conductor XLPE Sheathed
 
Standard Specifications:
 
SPLN 41 - 10: 1991
 
Conductor Type:
AAAC
 
Application:
Used conductors overhead distribution lines
 
Range Size
35 mm² - 300 mm²
 
Conductor Forms:
Stranded Sheathed XLPE
 
Standard Packaging
Haspel made of wood or Haspel Combination of Wood and Iron
Can be ordered with customizable features
 
Please Download Brochure below or our marketing sales hub through CONTACT FORM

 

Unduhan : 
PDF icon AAACS.v1.pdf (673.08 KB)

Welcome to PT. Prima Cable Indo

Versi ramah cetakPDF version

PT. Prima Cable Indo established since 1994 and engaged in electricity. We produce various types of cables for industrial, residential and apartement and office buildings.

Our office is located in Central Jakarta area and we have 2 factory location in Jati Uwung and Bandung. PT. Prima Cable Indo manufactures two brands of cables namely PUTERA CABLE and PRICA CABLE.

 

SNI Certification

Versi ramah cetakPDF version

About SNI Certification

Cu/PVC/PVC - f 450 / 750 V (NYYHY)

Versi ramah cetakPDF version
Material Inti: 
Cu
CU/PVC/PVC (NYYHY)
CONTROL CABLE FLEXIBLE WIRE
 
Standard Specification : 
SNI 04-6629.7-2006
IEC 60227-6:2001
 
Application :
Power cable: indoors, cable trunking, outdoors and buried in the ground for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely.
 
Special Features on Request :
 
Fire resistance
Oil resistance
UV resistance
Flame Retardant Cat A,B,C
Flame Retardant non-category
Heat resistance
Anti-termite
Anti-rodent
Low smoke zero halogen
Note: Conductor shape
 
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 sqmm supplied in non-compacted circular circular stranded (rm) conductor shape
25-500 sqmm supplied in non-compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
11.5 – 10 sqmm supplied in coil @ 100 meters
16 – 300 sqmm supplied in wooden drum @ 1000 meters
400 – 500 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%
Unduhan : 
PDF icon NYYHY.v1.pdf (1.97 MB)

Al/PVC/PVC 0.6/1 (1.2) kV (NAYY)

Versi ramah cetakPDF version
Sertifikasi: 
SNI IEC 60502-1
Material Inti: 
Al
0.6 / 1 kV, NAYY (Al / PVC / PVC)
Aluminium Konduktor, PVC Terisolasi, PVC berselubung)
 
 
Aplikasi:
Kabel daya: Di dalam ruangan, trunking kabel, di luar ruangan dan dikubur di tanah, untuk pembangkit listrik, industri dan switchgear dan juga untuk jaringan pasokan perkotaan, jika kerusakan mekanis tidak mungkin terjadi.
 
 
 
10 - 16 sqmm disediakan dalam bentuk konduktor sirkuler terdampar (rm) yang tidak terpadatkan
25 - 800 sqmm yang disuplai dalam bentuk pelepas sirkuler tidak terpadatkan (rm) atau dipadatkan melingkar (cm) konduktor
Packing Standar:
 
10 - 800 sqmm dipasok di drum kayu @ 1000 meter
Panjang Toleransi per drum ± 2%

HTLS (High Thermal Low Sag)

Versi ramah cetakPDF version
Material Inti: 
Al

ACSR

Versi ramah cetakPDF version
Material Inti: 
Al

Vision And Mision

English
Vision and mission
 
Vision
 
Putting forward quality in every real step, for optimal achievement.
 
 
Mission
 
Meet consumer expectations in terms of product quality, service and satisfaction.
 
Able to compete, both in domestic and international market
 
Establish a good and healthy cooperation with relations or partners to meet the growing market needs
 
It is the obligation of the whole range of companies from managers to executives to understand, implement and develop consistently quality standards in all divisions in order to achieve the set targets.

STANDAR PRODUK

Bahasa Indonesia

Berikut ini adalah standar organisasi yang kami gunakan dalam barang-barang produksi PT. Prima Cable Indo dengan referensi yang bervariasi

 

Code Name Note
SPLN Standard Perusahaan Listrik Negara
SNI Standard Nasional Indonesia
IEC International Electrotechnical Commission
VDE Verband des Deutscher Elektrotechniker
JIS Japanese Industrial Standard
BS British Standard
ICEA Insulated Cables Engineers Association
NEMA National Electrical Manufacturer Association
AS Australian Standard
ASTM American Society for Testing and Material
Other Specifications are available upon request

 

 

KEPUASAN PELANGGAN

Versi ramah cetakPDF version

PT. Prima Cable Indo, menjamin kepuasan pelanggan dengan menerapkan standar ISO 9001:2015 dalam memproduksi kabel-kabel bagi pelanggannya

Cu/PVC - f 450/750 V (NYAF)

Versi ramah cetakPDF version
Sertifikasi: 
SNI 04.6629.3 : 2006
Material Inti: 
Cu

CU/PVC   (NYAF )                        
Kondiktor Tembaga Fleksibel, Terinsulasi PVC
                        
Kabel Bangunan
450/750Volt        
                        
Spesifikasi Standar  :        
SPLN 42 -3:  1992        
SNI 04 - 6629.3  2006        
                        
Applikasi :        

Intalasi permanen dalam conduit 
                        
Bentuk Penghantar :        
1.5  - 240 sqmm disediakan dalam kemasan tergulung      
                        
Identifikasi Inti  :        
Hijau - Kuning , Merah atau Biru atau Kuning Terang atau Hitam Atau Colat atau Abu-abu.

Kemasan Standard :        
1.5  -  50  sqmm Sistem Koil       
70  -  240 sqmm Atau Drum Kayu /  Haspel
                        
Spesifikasi Dapat Disesuaikan berdasarkan permintaan (B)

 
Tanggal Kegiatan : 
Rabu, Februari 15, 2017
Unduhan : 
PDF icon NYA-NYAF.v1.pdf (1.01 MB)

Cu/PVC/SWA/PVC 0.6/1 (1.2) kV (NYRGbY)

Versi ramah cetakPDF version
Material Inti: 
Cu
Cu/XLPE/PVC/[SWA / AWA]/PVC
 
Distribution cable for industry constructions and switching boxes. For fixed installation inside of buildings, 
direct burial in earth, in water as well as in concrete and for heavy duty mechanical load.

Cu/PVC - f 450/750 V (NYZ)

Versi ramah cetakPDF version
Material Inti: 
Cu
CU/PVC 
Flexible Copper Conductor, PVC Insulated
 
Applications:
• Power cord or internal wiring with low mechanical stress for electrical
equipments, machineries, distribution panels, luminaires and other electrical
used in dry indoor premises, substitutes NYA.
• Permanent instalation in conduit, inherently flame retardant in compliance
with IEC 60332-1. (I)
 

Al/PVC/PVC 0.6/1 (1.2) kV (NAYY)

Versi ramah cetakPDF version
Material Inti: 
Al

0.6/1 kV, NAYY (Al / PVC / PVC)
Aluminium Conductor, PVC Insulated, PVC Sheathed)
Standard Specification : SPLN 43 – 1 & IEC 60502 – 1

Application :
Power cable : Indoors, cable trunking, outdoors and burried in the ground, for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely.

Special Features on Request :

Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Note: Conductor shape

10 – 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 – 800 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :

10 – 800 sqmm supplied in wooden drum @ 1000 meters
Length Tolerance per drum ± 2%

Sertifikasi LMK

Bahasa Indonesia

Tentang Kami

Bahasa Indonesia

Prima Cable Indo adalah perusahaan yang bergerak dibidang manufaktur Kabel Listrik dan Telekomunikasi yang dibangun pada tahun 1994. Perusahaan yang dulu bernama Putra Ometraco Elektrik ini telah menjadi salah satu produsen kabel dengan teknologi dan kualitas yang tinggi. Produk kami meliputi kabel listrik bervoltase rendah dan menengah, kabel telekomunikasi yang semuanya di desain sesuai standar nasional maupun internasional seperti JIS, VDE, SPLN (LMK).rima Cable Indo memiliki kantor pusat di Jakarta dengan fasilitas operasional di Zona Industri Jatiuwung, Tangerang Banten - Indonesia.

Tangerang Factory

English
Alamat
Alamat : 
Tangerang Factory
Desa Gebang Raya Jatiuwung Industrial Zone
15132 Tangerang , BT
Indonesia
Phone: (021) 5901453
Banten ID

LV PVC INSULATION CABLES

Versi ramah cetakPDF version

Kabel lapis baja PVC untuk digunakan pada instalasi tetap di kawasan industri, bangunan dan aplikasi serupa. Mereka mungkin dipasang di udara, di atas baki, dipotong langsung atau dikubur di tanah.

NFA2X-T

Versi ramah cetakPDF version
Material Inti: 
Al
BUILDING WIRE 
300 /  500 V
 
Spesifikasi Standard :
 
 
Aplikasi :
Koneksi lokasi indor atau kebutuhan yang portable
 
Bentuk Konduktor :
2,3,4,5 x (0.75 mm2 - 2.5 mm2)
 
Kemasan Standar :
1.5 - 10 sqmm Coil System
16 - 400 sqmm Wooden Drum
 
Spesifikasi spesial dapat diminta
Unduhan : 
PDF icon NFA2X-T.v1.pdf (1.57 MB)

ISO 9001:2015 Quality Management Compliance

Versi ramah cetakPDF version

ISO 9000 is a set of standards for quality management systems (QMS). ISO 9000 formulated by TC 176 ISO, the international organization in the field of standardization. ISO 9000 was first issued in 1987 by the International Organization for Standardization Technical Committee (ISO / TC) 176. [1] ISO / TC is responsible for the standards of the quality management system. [1] ISO / TC 176 establishes a review cycle every five years, to ensure that ISO 9000 standards will be up to date and relevant to the organization. [1] Revisions to ISO 9000 standards have been made in 1994 and 2000. [1]

  •     the existence of a set of procedures covering all important processes in the business;
  •     supervision in the manufacturing process to ensure that the system produces quality products;
  •     keeping important data and archives well;
  •     inspection of goods that have been produced to locate the damaged units, with correct corrective action if necessary;
  •     regularly review the effectiveness of each process and the quality system itself.

 

ISO 9001:2015 Quality Management

Valid : 29 November 2017 to 14 December 2018

Perusahaan Listrik Negara

Versi ramah cetakPDF version
Perusahaan Listrik Negara (abbreviated as PLN) or its official name is PT. PLN (Persero) is a SOE that takes care of all aspects of electricity in Indonesia.
 
Unit PT. PLN (Persero) is divided into several Territories to handle Generation, Distribution (Transmission) and Expense Setting, and Distribution to customers. Specifically for areas with interconnected Java-Bali electricity, the units are individually divided, for individual generation, separate transmission, individual load and separate distribution arrangements. Especially for power generation most power generation in Indonesia supplied by Private Company although there are some owned by PLN. For Sumatra transmission there is a parent unit of PLN P3B Sumatra, but for Distribution business is still in the main unit of the Region (there is no unit of distribution). (Description: For Electrical Interconnection Java-Bali PLN Unit is in Roman I, II, and III.For areas other than Java-Bali PLN unit named region in roman V)
 
Below are the units under PT. PLN (Persero):
 
I. Group of Distribution Units [edit | edit source]
PLN Distribution of DKI Jakarta, domiciled in Jakarta
PLN Distribution West Java, based in Bandung
PLN Distribution Banten, domiciled in Serang [7]
PLN Distribution Central Java and Yogyakarta, based in Semarang
PLN Distribution East Java, domiciled in Surabaya
PLN Distribution Bali, based in Denpasar
PLN Distribution Lampung, located in Bandar Lampung

Cu/PVC/SWA/PVC 0.6/1 (1.2) kV (NYRGbY)

Versi ramah cetakPDF version
Material Inti: 
Cu
Cu/XLPE/PVC/[SWA / AWA]/PVC
 
Distribution cable for industry constructions and switching boxes. For fixed installation inside of buildings, 
direct burial in earth, in water as well as in concrete and for heavy duty mechanical load.

Cu/PVC - f 450/750 V (NYZ)

Versi ramah cetakPDF version
Material Inti: 
Cu
CU/PVC 
Flexible Copper Conductor, PVC Insulated
 
Applications:
• Power cord or internal wiring with low mechanical stress for electrical
equipments, machineries, distribution panels, luminaires and other electrical
used in dry indoor premises, substitutes NYA.
• Permanent instalation in conduit, inherently flame retardant in compliance
with IEC 60332-1. (i)
 

NFA2X 0.6/1 (1.2) kV

Versi ramah cetakPDF version
Sertifikasi: 
SPLN 42 - 1 : 1993
Material Inti: 
Al
NFA2X
Konduktor Bundar Udara, Kabel Memutar
 
Aplikasi:
Konduktor bundel untuk jaringan distribusi overhead tanpa dan dengan pencahayaan publik. (antara kutub ke kutub)
 
Spesifikasi
 
SPLN 42-10: 1993
(Spesifikasi Lainnya tersedia atas permintaan)
Konstruksi
 
Konduktor
Stranded All Aluminium Conductor (AAC)
Isolasi
 
Menerapkan XLPE
 
Klasifikasi
 
Kabel Tegangan Rendah

AFILIASI

Bahasa Indonesia

About Us

English

Prima Cable Indo is a company engaged in manufacturing Electric and Telecommunication Cables built in 1994. The company formerly known as Putra Ometraco Elektrik has become one of the cable manufacturers with high technology and quality. Our products include low-and medium-voltage power cables, telecommunication cables all of which are designed according to national and international standards such as JIS, VDE, SPLN (LMK) .rima Cable Indo has headquarters in Jakarta with operational facilities at Jatiuwung Industrial Zone, Tangerang Banten - Indonesia.

PABRIK TANGERANG

Bahasa Indonesia
Alamat
Alamat : 
PABRIK TANGERANG
Jl. Kawasan Industri Keroncong Kp. Gebang Raya Kelurahan Gebang Raya Kecamatan Priuk Tangerang
15132 Kota Tangerang , BT
Indonesia
Phone: + 62 21 5901453, 59309178
Fax: + 62 21 5901455
6° 10' 35.976" S, 106° 35' 17.5164" E
Banten ID

Media Sosial

Versi ramah cetakPDF version

<div>
&lt;div id="social-link"&gt;&lt;div class="social-btns"&gt;&lt;a class="btn facebook" href="#"&gt;&lt;i class="fa fa-facebook"&gt;&lt;/i&gt;&lt;/a&gt;&lt;a class="btn linkedin" href="#"&gt;&lt;i class="fa fa-linkedin"&gt;&lt;/i&gt;&lt;/a&gt;&lt;a class="btn youtube" href="#"&gt;&lt;i class="fa fa-youtube"&gt;&lt;/i&gt;&lt;/a&gt; &lt;/div&gt;</div>
<div>
&nbsp; &nbsp; &nbsp; &lt;/div&gt;</div>

LV XLPE INSULATION CABLES

Versi ramah cetakPDF version

Tentang kabel insulasi XLPE

NFA 2X/T

Versi ramah cetakPDF version
Material Inti: 
Al
NFA2X-T 
ALUMUNIUM TWISTED CABLE NEUTRAL MESSGENGER
 
Standard Specification : 
SPLN 42-10 : 1993 
 
Type of Conductor :
Alumunium EC 1350 
 
Type of Messenger : 
Alumunium Aloy 6201 
 
Conductor Shape : 
Round Stranding 
 
Application :
Used for overhead distributions. Areal Messenger provides exellent tension to avoid sanging between potes. 
 
Size Range : 
2 x 25 + 25 mm
2 x 35 + 25 mm
2 x 50 + 35 mm
2 x 70 + 50 mm 
3 x 25 + 25 mm
3 x 35 + 25 mm  
3 x 50 + 35 mm
3 x 70 + 50 mm
 
Identification of Core : 
Two and Three Core Phase and one Messenger
 
Standard Packing : 
Wooden Drum 
 
Unduhan : 
PDF icon NFA2X-T.v1.pdf (1.57 MB)

Cu/PVC 450 / 750 V (NYA)

Versi ramah cetakPDF version
Material Inti: 
Cu

Cu/PVC ( NYA )
Copper Conductor, PVC Insulated

Building Wire
450 V / 750 V

Standard Specificatiob :
SNI 6629.3 - 2006

Application :
Permanent instalation in consuit or Exposes wiring in drying location

Condcutor Shape :
1.5 - 10 sqmm supplied in solid (re) or circular stranded (rm)
16 - 400 sqmm supplied in curcullar stranded (rm)

Standard Packing :
1.5 - 10 sqmm Coil System
16 - 400 sqmm Wooden Drum (B)

 

Unduhan : 
PDF icon NYA.v1.pdf (333.75 KB)

Cu/PVC/PVC 0.6/1 (1.2) kV (NYY)

Versi ramah cetakPDF version
Sertifikasi: 
SNI IEC 60502-1 : 2009
SPLN 43 - 1 : 1994
Material Inti: 
Cu

CU/PVC/PVC ( NYY )
Konduktor Tembaga dengan terinsulasi PVC dan dibungkus dengan PVC

Kabel Tegangan Rendah Tanpa Pelindung 0.6 / 1 KV

Spesifikasi Standar
SPLN       43 - 1 : 1994
SNI IEC 60502 - 1 : 2009

Instalasi dalam ruang dan luar ruang pada permukaan dimana tidak terkena bahan yang merusak secara kimia

Bentuk Konduktor :
1.5 - 10 mm supplied in solid  round engkel (re) circular stranded round multi (rm)
16 - 35  mm supplied in circullar stranded round multi (rm)
50 - 300 mm supplied in sector shape stranded sector multi (sm) conductor

Paking Standard :
- Koil
- Drum kayu ( dengan ukuran tergantung persediaan)

Fitur dapat disesuaikan berdasarkan permintaan (B)

 

Unduhan : 
PDF icon NYY.v1.pdf (1.36 MB)

NFA2X 0.6/1 (1.2) kV

Versi ramah cetakPDF version

NFA2X
Aerial Bundled Conductor , Twisted Cable

Application :
Bundle conductor for overhead distribution network without and with public lighting. (between pole to pole)

Specification

SPLN 42-10 : 1993
( Other Specifications are available upon request )
Construction

Conductor
Stranded All Aluminium Conductor (AAC)
Insulation
Extrude of XLPE
Classification
Low Voltage Cable

Audit SMK3 Sistem Manajemen Keselamatan dan Kesehatan Kerja Memenuhi Syarat

Bahasa Indonesia
SMK3 diwajibkan  bagi perusahaan, mempekerjakan lebih dari 100 org dan mempunyai tingkat potensi bahaya tinggi. Untuk itu perusahaan diwajibkan menyusun Rencana K3, dalam menyusun rencana K3 tersebut,  pengusaha  melibatkan Ahli K3, Panitya Pembina Keselamatan dan Kesehatan Kerja(P2K3), Wakil Pekerja dan Pihak Lain yag terkait
Surat Keterangan Audit SMK3 Sistem Manajemen Keselamatan dan Kesehatan Kerja
 
Berlaku : 11 Desember 2017
 

BRANCH OFFICE & FACTORY BANDUNG

English
Address
Alamat : 
BRANCH OFFICE & FACTORY BANDUNG
Jl. Raya Sapan No 100 Desa Tegal Luar Bojongsoang
40297 Bandung , JR
Indonesia
Phone: +62 22 87528467
Fax: +62 22 87528468
Jawa Barat ID

FACTORY TANGERANG

Versi ramah cetakPDF version
English
Address
Alamat : 
PABRIK TANGERANG
Jl. Kawasan Industri Keroncong Kp. Gebang Raya Kelurahan Gebang Raya Kecamatan Priuk Tangerang
15132 Kota Tangerang , BT
Indonesia
Phone: + 62 21 5901453, 59309178
Fax: + 62 21 5901455
6° 10' 35.976" S, 106° 35' 17.5164" E
Banten ID

SPECIAL CABLE

Versi ramah cetakPDF version

SPECIAL CABLE

KABEL ABC

Versi ramah cetakPDF version
Material Inti: 
Al
Deskripsi
Kabel udara terbungkus merupakan kabel jalur powe yang dibungkus dengan beberapa fasa  secara rapat bersamaan, biasanya dengan bare condutor yang netral. ini berbeda dengan kabel tidak terbungkus yang hanya dibatasi dengan udara. dengan demikian setiap konduktornya dibungkus secara bersamaan terhadap kabel inti yang netral tidak terinsulasi.
 
Aplikasi :
Dirancang untuk perumahan dan daerah pedesaan untuk mengurangi gangguan loncatan api listrik
 
Tipe Konduktor
Aluminum
 
Standar Aplikasi :
SNI
 
Ukuran  :
Berdasarkan permintaan
 
Jumlah Inti
1 - 4 Inti
 
Identifikasi Inti :
Terpilin dengan dibungkus insulasi terhadap inti netral yang tanpa insulasi
 
Standard Kemasan
Drum terbuat dari kayu atau Drum Kombinasi Kayu dan Besi

Dapat dipesan dengan fitur yang bisa disesuaikan

Harap Download Brosur dibawah ini atau hub marketing sales kami melalui FORM KONTAK

 

KABEL LISTRIK PRICA

Versi ramah cetakPDF version

KABEL PRICA adalah Kabel produksi PT. Prima Cable Indo , fokus kepada pemakaian residential dan gedung dan mempunyai semua parameter yang terkait dengan aplikasi

Cu/PVC 450 / 750 V (NYA)

Versi ramah cetakPDF version
Material Inti: 
Cu

Cu/PVC ( NYA )
Konduktor Tembaga dengan insulasi PVC

Tegangan Kerja
450 V / 750 V

Spesifikasi Standar:
SNI 6629.3 - 2006

Aplikasi Application :
Instlasi tetap dalam conduit atau dipasang pada ruang terbuka yang kering

Bentuk Konduktor  :
1.5 - 10 mm2 dengan padat (re)atau terpilin melingkar (rm)
16 - 400 mm2 tersedia dengan terpilin melingkar (rm)

Kemasan Standard :
1.5 - 10 sqmm Sistem Gulung
16 - 400 sqmm Drum Kayu
  

Unduhan : 
PDF icon NYA.v1.pdf (333.75 KB)

Cu/PVC/PVC 0.6/1 (1.2) kV (NYY)

Versi ramah cetakPDF version
Sertifikasi: 
SNI IEC 60502-1 : 2009
SPLN 43 - 1 : 1994
Material Inti: 
Cu
Core Materials:
Cu
CU / PVC / PVC (NYY)
Copper conductor with PVC insulated and wrapped with PVC
 
Low Voltage Cable Without Protector 0.6 / 1 KV
 
Standard Specifications
SPLN 43 - 1: 1994
SNI IEC 60502 - 1: 2009
 
Installation in space and outdoors on surfaces where not exposed to chemically damaging materials
 
Conductor Forms:
1.5 - 10 mm supplied in solid round ankle (re) circular stranded round multi (rm)
16 - 35 mm supplied in circularar stranded round multi (rm)
50 - 300 mm supplied in sector shape multi stranded sector multi (sm) conductor
 
Paking Standard:
- Koil
- Wood drum (with stock-dependent size)
 
Features can be customized on request (B)
Unduhan : 
PDF icon NYY.v1.pdf (1.36 MB)

Al/XLPE/SWA/PVC 0.6/1 (1.2) kV (NA2XRGbY)

Versi ramah cetakPDF version
Material Inti: 
Al

Al/XLPE/SWA/PVC   0.6/1 (1.2) kV  (NA2XRGbY)

Twin-Cores : Light-Blue, Black

Three-Cores :
♦ System I

Green with yellow stripe (G/Y), Blue, Brown
♦ System 0

Brown, Black, Grey

Four-Cores :
♦ System I

Green with yellow stripe (G/Y), Brown, Black, Grey
♦ System 0

Blue, Brown, Black, Grey

Five-Cores :
♦ System I

Green with yellow stripe (G/Y), Blue, Brown, Black, Grey
♦ System 0

Blue, Brown, Black, Grey, Black

Other colour are available on request.

Symbol    :    
Size Ranged    :    5 x 1.5 ... 35 mm2mm²
4 x 1.5 ... 300 mm2mm²
3 x 1.5 ... 300 mm2mm²
2 x 1.5 ... 300 mm2mm²
Applicable Standard    :    
Other Specification are available on request

Application    :    Indoor and Outdoor ,
Installation direct bureal
Preferaby use where considerable mechanical stress must be envisaged

ISO 14001:2015 Manajemen Lingkungan

Bahasa Indonesia

Berlaku : 28 November 2017 s/d 11 November 2020

ISO 14001 mendefinisikan kriteria untuk EMS. Ini tidak menyatakan persyaratan untuk kinerja lingkungan melainkan memetakan kerangka kerja yang dapat diikuti perusahaan atau organisasi untuk menyiapkan EMS yang efektif. Hal ini dapat digunakan oleh organisasi manapun yang ingin meningkatkan efisiensi sumber daya, mengurangi limbah, dan mengurangi biaya. Menggunakan ISO 14001 dapat memberikan kepastian kepada manajemen perusahaan dan karyawan serta pemangku kepentingan eksternal bahwa dampak lingkungan diukur dan ditingkatkan. [6] ISO 14001 juga dapat diintegrasikan dengan fungsi manajemen lainnya dan membantu perusahaan dalam memenuhi tujuan lingkungan dan ekonomi mereka.

 
ISO 14001, seperti standar ISO 14000 lainnya, bersifat sukarela [11], dengan tujuan utamanya membantu perusahaan dalam terus meningkatkan kinerja lingkungan mereka dan mematuhi undang-undang yang berlaku. Organisasi tersebut menetapkan target dan ukuran kinerjanya sendiri, dan standar tersebut menyoroti apa yang perlu dilakukan organisasi untuk memenuhi tujuan tersebut, dan untuk memantau dan mengukur situasinya. [11] Standar tersebut tidak berfokus pada ukuran dan sasaran kinerja lingkungan, namun juga organisasi. Standar tersebut dapat diterapkan pada berbagai tingkat dalam bisnis, mulai dari tingkat organisasi hingga tingkat produk dan layanan.
 
ISO 14001 dikenal sebagai standar sistem manajemen generik, yang berarti relevan dengan organisasi yang berusaha memperbaiki dan mengelola sumber daya secara lebih efektif. Ini termasuk:
 
satu situs ke perusahaan multinasional besar
perusahaan berisiko tinggi terhadap organisasi layanan berisiko rendah
industri manufaktur, proses, dan jasa, termasuk pemerintah daerah
semua sektor industri, termasuk sektor publik dan swasta
produsen peralatan asli dan pemasoknya
Semua standar ditinjau secara berkala oleh ISO untuk memastikan mereka tetap memenuhi persyaratan pasar. Versi saat ini adalah ISO 14001: 2015, dan organisasi sertifikasi diberi masa transisi tiga tahun untuk menyesuaikan sistem manajemen lingkungan mereka dengan edisi baru standar ini. Versi baru dari ISO 14001 berfokus pada peningkatan kinerja lingkungan daripada perbaikan sistem manajemen itu sendiri. [12] Ini juga mencakup beberapa update baru yang semuanya bertujuan untuk membuat pengelolaan lingkungan lebih komprehensif dan relevan dengan rantai pasokan. Salah satu pembaruan utama meminta organisasi untuk mempertimbangkan dampak lingkungan selama keseluruhan siklus hidup, walaupun tidak ada persyaratan untuk benar-benar menyelesaikan analisis siklus hidup. Selain itu, komitmen manajemen puncak dan metode penilaian kepatuhan juga telah diperkuat. Perubahan signifikan lainnya terkait ISO 14001 dengan struktur sistem manajemen umum, yang diperkenalkan pada tahun 2015, yang disebut Struktur Tingkat Tinggi. Baik ISO 9001 dan 14001 menggunakan struktur yang sama, membuat implementasi dan audit lebih seragam. Standar baru ini juga mewajibkan pemegang sertifikat untuk menentukan risiko dan peluang dan cara mengatasinya

KANTOR CABANG & PABRIK BANDUNG

Bahasa Indonesia
Alamat
PT. Prima Cable Indo memiliki pabrik di daerah Bandung Selatan, tepatnya berada di daerah Sapan dan telah berdiri sejak tahun 2009. Adapun Pabrik ini mempunyai luas 9 hektar dan kedepannya akan memiliki sampai 3 lokasi produksi.
dengan beroperasi 24 selama hari kerja, pabrik ini akan mampu memenuhi permintaan kebutuhan akan kabel-kabel bagi konsumen. Memiliki tempat peritirahatan dan danau yang cukup luas lengkap dengan hewan-hewan 
yang peliharaan disekitarnya meliputi bebek, ayam serta ikan yang bisa dipancing setiap saat.
 
Adapun pabrik bandung memiliki mesin-mesin terbaru yang akan terus ditambah seiring dengan peningkatan permintaan kebutuhan konsumen, mulai dari kabel telekomunikasi, konduktor 
kabel listrik dan fiber optik. Penambahan mesin-mesin ini akan memberikan diversifikasi produk dari PT. Prima Cable Indo dan tentu meningkatkan kepuasan konsumen terhadap ketersediaan barang produksi yang semakin berkualitas
 
Demikian "PCI Bandung" disebut oleh karyawannya, manajemen pabrik memberikan fasilitas peristirahatan yang nyaman bagi para tamu, karyawan internal atau pihak-pihak yang terkait dalam sinergi kemajuan perusahaan PT. Prima Cable Indo
 
 

 

Alamat : 
KANTOR CABANG & PABRIK BANDUNG
Raya Sapan No 100 Street. Rancakaso Desa Tegalluar Bojongsoang
40297 Bandung , JR
Indonesia
Phone: +62 22 87528467
Fax: +62 22 87528468
Jawa Barat ID

Form Pendaftaran

Versi ramah cetakPDF version
 
1 Start 2 Start 3 Complete

Quality Control

Versi ramah cetakPDF version

We are continuously committed to maintaining, supporting, checking and improving and maintaining our quality systems to meet industry specifications and quality standards demanded by customers.
From the outset, the quality management system has been documented and implemented and practiced at every stage of plant operation.
The main focus is on process control through a dynamic quality assurance system, product development and continuous improvement in every manufacturing process
Quality remains and will continue to be our top priority at PT. Prima Cable Indo.

KABEL SPESIAL

Versi ramah cetakPDF version

KABEL SPESIAL merupakan kabel yang bisa dikustomisasi berdasarkan permintaan

ABC CABLE

Versi ramah cetakPDF version
Material Inti: 
Al
Description :
Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. This contrasts with the traditional practice of using uninsulated conductors separated by air gaps. This variation of overhead power lines utilizes the same principles as bundled conductors, except that they are closer together to the point of touching but each conductor is surrounded by an insulating layer (except for the neutral line).
 
Application :
Designed for residential and rural areas for reducing the bushfire hazards
 
Type Of Conductor :
Aluminum
 
Standard Application :
SNI
 
Size Range :
On Request
 
Conductor Shape :
Single Core
 
Identification of Core :
Stranded
 

Standard Packing :
Wooden drum or Combination Steel Wooden Drum

Special Feature on Request

Please Download Brochure below or Contat Our Sales via Contact Us Menu

 
 

Standarization 1

Versi ramah cetakPDF version

About Standarization

PRICA ELECTRICAL CABLE

Versi ramah cetakPDF version

PRICA ELECTRICAL CABLE is a product of PT. Prima Cable Indo which are design and application for Residential and Commercial Building

Cu/PVC/CTS/PVC 0.6/1 (1.2) kV (NYSY)

Versi ramah cetakPDF version
Material Inti: 
Cu
0.6/1 kV, NYSY (Cu / PVC / CTS / PVC)
(Copper Conductor, PVC Insulated, Copper Tape Screen, PVC Sheathed)
Standard Specification : IEC 60502 – 1
 
Application :
For power plants and switchgear as well as for installation of sub-station; for installation indoors in confinned spaces and cable channels because of small bending radius. As burried cable, because of its light weight prefered in where installation is difficult.
 
Special Features on Request :
 
Fire Resistance
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Note: Conductor shape
 
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 – 500 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
1.5 – 300 sqmm supplied in wooden drum @ 1000 meters
400 – 500 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%

Cu/PVC/SFA/PVC 0.6/1 (1.2) kV (NYFGbY)

Versi ramah cetakPDF version
Material Inti: 
Cu
Cu / PVC / SFA / PVC (NYFGbY)
TEGANGAN RENDAH KABEL ARMORED
 
Spesifikasi Standar:
SPLN 43-2: 1994
SNI IEC 60505 - 1: 2009
 
Aplikasi:
Indoor dan Outdoor induct Installatiom bureal langsung sebaiknya menggunakan tempat strees mekanis yang cukup besar harus dipertimbangkan.
 
Konduktor Bentuk:
1,5 - 10 sqmm disuplai solid (re) atau circular stranded (rm).
16 - 35 sqmm disertakan dalam sirkuler terdampar (rm).
50 - 300 sqmm dipasok dalam bentuk sektor terdampar (sm).
Single Core dipasok dalam sirkuler terdampar (rm).
 
Packing Standar:
- Drum Kayu.
Unduhan : 
PDF icon NYFGbY.v1.pdf (1.31 MB)

Al/XLPE/SWA/PVC 0.6/1 (1.2) kV (NA2XRGbY)

Versi ramah cetakPDF version
Material Inti: 
Al

Al/XLPE/SWA/PVC   0.6/1 (1.2) kV  (NA2XRGbY)

Twin-Cores : Light-Blue, Black

Three-Cores :
♦ System I

Green with yellow stripe (G/Y), Blue, Brown
♦ System 0

Brown, Black, Grey

Four-Cores :
♦ System I

Green with yellow stripe (G/Y), Brown, Black, Grey
♦ System 0

Blue, Brown, Black, Grey

Five-Cores :
♦ System I

Green with yellow stripe (G/Y), Blue, Brown, Black, Grey
♦ System 0

Blue, Brown, Black, Grey, Black

Other colour are available on request.

Symbol    :    
Size Ranged    :    5 x 1.5 ... 35 mm2mm²
4 x 1.5 ... 300 mm2mm²
3 x 1.5 ... 300 mm2mm²
2 x 1.5 ... 300 mm2mm²
Applicable Standard    :    
Other Specification are available on request

Application    :    Indoor and Outdoor ,
Installation direct bureal
Preferaby use where considerable mechanical stress must be envisaged

ISO 9001:2015 Standar Manajemen Mutu

Bahasa Indonesia
ISO 9001:2015 Manajemen Mutu
 
ISO 9000 adalah kumpulan standar untuk sistem manajemen mutu (SMM). ISO 9000 yang dirumuskan oleh TC 176 ISO, yaitu organisasi internasional di bidang standardisasi. ISO 9000 pertama kali dikeluarkan pada tahun 1987 oleh International Organization for Standardization Technical Committee (ISO/TC) 176.[1] ISO/TC inilah yang bertanggungjawab untuk standar-standar sistem manajemen mutu.[1] ISO/TC 176 menetapkan siklus peninjauan ulang setiap lima tahun, guna menjamin bahwa standar-standar ISO 9000 akan menjadi up to date dan relevan untuk organisasi.[1] Revisi terhadap standar ISO 9000 telah dilakukan pada tahun 1994 dan tahun 2000.[1]
  •     adanya satu set prosedur yang mencakup semua proses penting dalam bisnis;
  •     adanya pengawasan dalam proses pembuatan untuk memastikan bahwa sistem menghasilkan produk-produk berkualitas;
  •     tersimpannya data dan arsip penting dengan baik;
  •     adanya pemeriksaan barang-barang yang telah diproduksi untuk mencari unit-unit yang rusak, dengan disertai tindakan perbaikan yang benar apabila dibutuhkan;
  •     secara teratur meninjau keefektifan tiap-tiap proses dan sistem kualitas itu sendiri.
Berlaku : 29 November 2017 s/d 14 Desember 2018

Kabel Listrik Prica

Bahasa Indonesia

KABEL PRICA adalah Kabel produksi PT. Prima Cable Indo , fokus kepada pemakaian residential dan gedung dan mempunyai semua parameter yang terkait dengan aplikasi

Kontak Kami

Versi ramah cetakPDF version
 
1 Start 2 Tinjauan 3 Complete
0%
11 + 4 =

ACSR/AS (Al/SA1A)

Versi ramah cetakPDF version
Material Inti: 
Al

ACSR / AS ( A1 / SA1A )
Konduktor Alumunium dengan Besi Pengikat Penguat Alumunium (dengan pelumas)

Jangkauan Ukuran  : 100 - 630

Spesifikasi :
SPLN T3.001 - 1 : 2015
ASTM B 549
DIN 48204

Aplikasi  :
Digunakan untuk jaringan transmisi  ruang terbuka
Sebagai konduktor listrik

Identifikasi :
Konduktor Tunggal

Standard Kemasan
Drum terbuat dari kayu atau Drum Kombinasi Kayu dan Besi

Dapat dipesan dengan fitur yang bisa disesuaikan

Harap Download Brosur dibawah ini atau hub marketing sales kami melalui FORM KONTAK

Unduhan : 
PDF icon ACSR.v1.pdf (401.09 KB)

LV XLPE INSULATION CABLES

Versi ramah cetakPDF version

About XLPE LOW VOLTAGE  CABLE ( XLPE LV )

KABEL TAHAN API

Versi ramah cetakPDF version

Tentang Kabel Tahan Api

Profil Perusahaan

Versi ramah cetakPDF version

Tentang Perusahaan 

KABEL LISTRIK PUTERA

Versi ramah cetakPDF version

Kabel Putera adalah kabel produksi PT. Prima Cable Indo yang dibuat untuk memenuhi kebutuhan-kebutuhan penyedia jasa layanan listrik dan kebutukan pembangunan Nasional di negara Republik Indonesia serta mempunyai sepsifikasi yang sesuai dengan SPLN, SNI mapun LMK 

Cu/PVC/CTS/PVC 0.6/1 (1.2) kV (NYSY)

Versi ramah cetakPDF version
Material Inti: 
Cu
0.6/1 kV, NYSY (Cu / PVC / CTS / PVC)
(Copper Conductor, PVC Insulated, Copper Tape Screen, PVC Sheathed)
Standard Specification : IEC 60502 – 1
 
Application :
For power plants and switchgear as well as for installation of sub-station; for installation indoors in confinned spaces and cable channels because of small bending radius. As burried cable, because of its light weight prefered in where installation is difficult.
 
Special Features on Request :
 
Fire Resistance
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Note: Conductor shape
 
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 – 500 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
1.5 – 300 sqmm supplied in wooden drum @ 1000 meters
400 – 500 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%

Cu/PVC/SFA/PVC 0.6/1 (1.2) kV (NYFGbY)

Versi ramah cetakPDF version
Material Inti: 
Cu
Cu/PVC/SFA/PVC (NYFGbY)
LOW VOLTAGE ARMOURED CABLE
 
Standard Spesification : 
SPLN 43-2 :  1994
SNI IEC 60505 - 1 : 2009
 
Application : 
Indoor and Outdoor induct Installatiom direct bureal preferably use where considerable mechanical strees must be envisaged.
 
Conductor Shape : 
1.5 - 10 sqmm supplied in solid (re) or circular stranded (rm).
16 - 35 sqmm supplied in circular stranded (rm).
50 - 300 sqmm supplied in sector shape stranded (sm). 
Single Core supplied in circular stranded (rm). 
 
Standard Packing :
- Wooden Drum (will be supplied on available leght).
Unduhan : 
PDF icon NYFGbY.v1.pdf (1.31 MB)

BCC - 1/2 HARD

Versi ramah cetakPDF version
Material Inti: 
Cu

KEPUASAN PELANGGAN

Bahasa Indonesia

PT. Prima Cable Indo, menjamin kepuasan pelanggan dengan menerapkan standar ISO 9001:2015 dalam memproduksi kabel-kabel bagi pelanggannya

PRICA ELECTRICAL CABLE

English

PRICA ELECTRICAL CABLE is a product of PT. Prima Cable Indo which are design and application for Residential and Commercial Building

Contact Us

Versi ramah cetakPDF version
 
1 Start 2 Start 3 Complete
1 + 0 =

LV PVC INSULATION CABLES

Versi ramah cetakPDF version

XLPE Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. They may be installed in air, on trays, clipped direct or be buried in the ground

FIRE RESISTANT CABLE

Versi ramah cetakPDF version

About FIRE RESISTANT CABLE

Company Profile

Versi ramah cetakPDF version

About Company Profile

PUTERA ELECTRICAL CABLE

Versi ramah cetakPDF version

PUTERA ELECTRICAL CABLE are range of brand product that suitable for large contraktor and electrical national company (PLN) and pass national product certification like : SNI, LMK, SPLN and etc.

Cu/PVC/CWS/PVC 0.6/1 (1.2) kV (NYCY)

Versi ramah cetakPDF version
Material Inti: 
Cu
0.6/1 kV, NYCY (Cu / PVC / CWS / PVC)
(Copper Conductor, PVC Insulated, Copper Wire Screen, PVC Sheathed)
Standard Specification : IEC 60502 – 1
 
Application :
For installation in the ground, indoors, cable trunking and outdoors if subsequent mechanical damage is likely, for urban networks, household feeder and street lighting.
 
Special Features on Request :
 
Fire Resistance
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Note: Conductor shape
 
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 – 500 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
1.5 – 240 sqmm supplied in wooden drum @ 1000 meters
300 – 500 sqmm supplied in wooden drum on available length (I)
Length Tolerance per drum ± 2%

Cu/XLPE/PVC 0.6/1 (1.2) kV (N2XY)

Versi ramah cetakPDF version
Material Inti: 
Cu

Spesifikasi Standar :
SNI IEC 60502 - 1 : 2009

Aplikasi :
Kabel Daya : Dalam Ruang, Jalur Kabel Gantung, Area Terbuka, ditanam dalam tanah, untuk stasiun daya, industri and peralihan seperti misalnya untuk menunjang jaringan daya diama tidak sering terjadi ganguan mekanis

Bentuk Konduktor :
Terpilin melingkar

Kemasan Standar:
Drum Kayu

Fitur Dapat Disesuaikan berdasarkan permintaan
 

Unduhan : 
PDF icon N2XY.v1_0.pdf (2.17 MB)

BCC - 1/2 HARD

Versi ramah cetakPDF version
Material Inti: 
Cu

KESELAMATAN & KEAMANAN

Bahasa Indonesia

Tim Keselamatan dan Kesehatan Kerja Prima Cable Indo (HSE) secara aktif meliput lingkup ini, berusaha memastikan penggunaan kabel dan kabel yang berkelanjutan di Indonesia. Komitmen yang diberikan oleh Prima Cable Indo juga diungkapkan melalui Sertifikasi Keamanan Lingkungan

High Standards

English

Prima Cable Indo manufactures cables by using high-strength copper alloys developed independently. While maintaining high conductivity, this wire has a doubling tensile strength and recurrent bending strength of the common alloy wire and its superior bending resistance ensures long life. Prima Cable Indo is able to adapt proposals for industrial robots, as well as various scenarios in which flexible cables are required.

Visi dan Misi

Versi ramah cetakPDF version

VISI & MISI
 
Visi :
Menjadi produsen kabel yang ternama di Indonesia
 
 
Misi :
1) Kontribusi dalam pembangunan perlistrikan dan telekomunikasi yang handal.
2) Membangun kesadaran personil dalam hal mutu, keselamatan dan kesehatan kerja serta perlindungan lingkungan hidup.
3) Membangun kerjasama dan kemitraan dengan prinsip win-win solution dengan para pemangku kepentingan.
4) Penerapan prinsip perbaikan berkelanjutan dalam hal kompetensi sumberdaya manusia, ilmu dan teknologi per-kabel-an, serta kehandalan infrastruktur  yang digunakan.

HIGH STANDARD

Versi ramah cetakPDF version

Prima Cable Indo memproduksi kabel dengan menggunakan kawat paduan tembaga berkekuatan tinggi yang dikembangkan secara independen. Sambil mempertahankan konduktivitas yang tinggi, kawat ini memiliki kekuatan tarik dan kekuatan lentur berulang dua kali lipat dari kawat paduan umum dan daya tahan lenturnya yang superior memastikan umur yang panjang. Prima Cable Indo mampu menyesuaikan proposal untuk robot industri, serta berbagai skenario di mana kabel fleksibel dibutuhkan.

KABEL LSOH

Versi ramah cetakPDF version

Tentang LSOH CABLE

Deskripsi :

 

Aplikasi :

 

Standar Aplikasi :

 

Jangkauan Ukuran  :

 

Bentuk Konduktor :

 

Identifikasi Inti :

 

Standard Package :

 

 

Harap Download Brosur dibawah ini atau hub marketing sales kami melalui FORM KONTAK

Company History

Versi ramah cetakPDF version

PT.Prima Cable Indo is a company engaged in the manufacturer of low and medium voltage cable with trademark PUTERA KABEL and PRICA KABEL standard SPLN and SNI. Currently we are continuing to invest in business development, establishing new machines and recruitment of human resources, to improve production capacity and quality for the better.

 

AAC (1350)

Versi ramah cetakPDF version
Sertifikasi: 
ASTM B 215 Part 1 : 1970
ASTM B 231 : 2004
IEC C 61089 : 1991
Material Inti: 
Al
AAC (1350)
All Aluminium Conductor
 
Application :
Overhead Conductor.
 
Classification :
Bare Conductor
 
Size Range : 
 35 - 1200 mm2
 
Construction :
Stranded All Aluminium Conductor

Standard Packing :
Haspel or Steel Haspel,

Special Feature on Request

Please Download Brochure below or Contat Our Sales via Contact Us Menu

Unduhan : 
PDF icon AAC.v1.pdf (724.77 KB)

Cu/PVC/CWS/PVC 0.6/1 (1.2) kV (NYCY)

Versi ramah cetakPDF version
Material Inti: 
Cu
0.6/1 kV, NYCY (Cu / PVC / CWS / PVC)
(Copper Conductor, PVC Insulated, Copper Wire Screen, PVC Sheathed)
Standard Specification : IEC 60502 – 1
 
Application :
For installation in the ground, indoors, cable trunking and outdoors if subsequent mechanical damage is likely, for urban networks, household feeder and street lighting.
 
Special Features on Request :
 
Fire Resistance
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Note: Conductor shape
 
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 – 500 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
1.5 – 240 sqmm supplied in wooden drum @ 1000 meters
300 – 500 sqmm supplied in wooden drum on available length (I)
Length Tolerance per drum ± 2%

Cu/XLPE/PVC 0.6/1 (1.2) kV (N2XY)

Versi ramah cetakPDF version
Material Inti: 
Cu

Standard Specification :
SNI IEC 60502 - 1 : 2009

Application :
Power cable : Indoor , cable trunking , outdoors and buried in the ground, for power station, industry and switchgear as well as for urban supply network, if mechanical damage in unlikely

Conductor Shape :
Circulair Stranded.

Standard Packing :
Wooden Drum

Special Feature on Request

Unduhan : 
PDF icon N2XY.v1_0.pdf (2.17 MB)

Statistic

Versi ramah cetakPDF version



OHSAS 18001:2007 Kesehatan dan Keselamatan

Bahasa Indonesia
Standar OHSAS 18000 menyediakan elemen-elemen sistem manajemen keselamatan yang efektif yang dapat diintegrasikan dengan sistem manajemen lain dan membantu organisasi mencapai kinerja kesehatan dan keselamatan kerja yang lebih baik dan tujuan ekonomi.
 
BS OHSAS 18001 menetapkan persyaratan untuk sistem manajemen K3 untuk membantu organisasi mengembangkan dan menerapkan kebijakan dan tujuan, yang mempertimbangkan persyaratan hukum dan informasi tentang risiko K3. Ini berlaku untuk semua jenis dan ukuran organisasi dan mengakomodasi beragam kondisi geografis, budaya dan sosial.
 
BS OHSAS 18002 memberikan panduan untuk menetapkan, menerapkan atau memperbaiki sistem manajemen yang didasarkan pada OHSAS 18001 dan menunjukkan keberhasilan penerapan OHSAS 18001.
 
OHSAS 18001 dapat disesuaikan dengan sistem manajemen ISO 9001 dan ISO 14001 yang ada. Secara historis banyak organisasi memulai dengan sistem manajemen mutu ISO 9001, kemudian menambahkan persyaratan pengelolaan lingkungan dari ISO 14001. Banyak organisasi sekarang melihat penerapan ketiga standar sekaligus yang dapat meminimalkan biaya dan gangguan. Standar dapat diintegrasikan menggunakan standar seperti BSI PAS 99.

Sertifikat OHSAS 18001:2007 Health - Safety

Berlaku : 28 November 2017 s/d 11 November 2020
 
SILAHKAN UNDUH  TANDA BUKTI SERTIFIKASI
 

AFFILIATES

English

AAAC-S

Versi ramah cetakPDF version
Sertifikasi: 
SPLN 41 - 10
Material Inti: 
Al
AAAC-S

All  Aluminium Alloy Conductor  XLPE Sheathed

Spesifikasi Standar : 

SPLN 41 - 10:1991

Jenis Konduktor:
AAAC
 
Aplikasi:
Digunakan  konduktor jalur distribusi overhead
 
Ukuran Rentang
35 mm² - 300 mm²
 
Konduktor Bentuk:
Stranded Sheathed XLPE
 
Standard Kemasan
Haspel terbuat dari kayu atau Haspel Kombinasi Kayu dan Besi

Dapat dipesan dengan fitur yang bisa disesuaikan

Harap Download Brosur dibawah ini atau hub marketing sales kami melalui FORM KONTAK

Unduhan : 
PDF icon AAACS.v1.pdf (673.08 KB)

ACSR/AS (Al/SA1A)

Versi ramah cetakPDF version
Material Inti: 
Al

ACSR / AS ( A1 / SA1A )
Aluminum Conductor With Aluminum Clad Steel Reinforced (with grease)

Type of Cable : 100 - 630

Spesification :
SPLN T3.001 - 1 : 2015
ASTM B 549
DIN 48204

Application :
Used for overhead transmission line
For electrical Conductor

Identification :
Single Conductor
Standard Packing :
Wooden drum or Combination Steel Wooden Dru,

Special Feature on Request

Please Download Brochure below or Contact Our Sales via Contact Us Menu

Unduhan : 
PDF icon ACSR.v1.pdf (401.09 KB)

OHSAS 18001:2007 Health - Safety Compliance

Versi ramah cetakPDF version

Certificate OHSAS 18001:2007 Health - Safety

valid : 28 November 2017 s/d 11 November 2020
 
 
 

BCC-SOFT

Versi ramah cetakPDF version
Material Inti: 
Cu

About  BCC

Cable Bare Copper Conductor (BCC) is a bare Copper Wire that is usually used for air ducts and ground cables.

 

Features

This type of BCC conductor is used for air channel power transmission.

 

Construction

Conductors: Seven copper or more wires of the same diameter in concentric layers.

 

Bare Copper Conductor - Hard (BCC-H)

Conductors having mechanical characteristics of at least 428 N / mm2. Maximum resistivity at 20 degrees Celsius is 0.01786 ohm.mm2 / m

 

Bare Copper Conductor - Half Hard (BCC-1 / 2H)

Conductors having minimal mechanical characteristics of 340 N / mm2. Maximum 410 N / mm2. Maximum resistivity at 20 degrees Celsius is 0.01784 ohm.mm2 / m

 

Annealed Copper Wire (BCC Soft)

This conductor has a maximum resistivity at 20 degrees Celsius is 0.017241 ohm.mm2 / m

 

Type:

BCC-1 / 2H

BCC-Soft

 

Specification

SPLN 41-4: 1981

SPLN 41-5: 1981

JIS C 3102

(Other specifications are also available on request)

 

Here for example BCC cable 120 mm2

Cu/PVC/DSTA/PVC 0.6/1 (1.2) kV (NYBY)

Versi ramah cetakPDF version
Material Inti: 
Cu
0.6 / 1 kV, NYBY (Cu / PVC / DSTA / PVC)
(Tembaga Konduktor, PVC Insulated, Double Steel Tape Armor, PVC Sheathed)
Spesifikasi Standar: IEC 60502 - 1
 
Aplikasi:
Untuk pemasangan di dalam ruangan, saluran kabel dan di ground, untuk instalasi industri, switchgear, dan pembangkit tenaga listrik, jika ada risiko kerusakan mekanis rendah dapat terjadi.
 
Fitur Khusus Permintaan:
 
Tahan api
Perlawanan Minyak
Perlawanan UV
Flame Retardant Cat. A, B, C
Flame Retardant Non Kategori
Perlawanan panas
Anti Rayap
Anti Rodent
Low Smoke Zero Halogen
Catatan: Bentuk konduktor
 
1,5 - 10 sqmm yang disuplai dalam bentuk konduktor sirkular terdampar padat (re) atau non compacted circular stranded (rm) 16 sqmm yang disuplai dalam bentuk konduktor terdampar sirkuler (rm) yang tidak dipadatkan.
25 - 300 sqmm yang disuplai dalam bentuk konduktor sirkuler yang tidak terpadatkan (rm) atau dipadatkan melingkar (cm) konduktor
Packing Standar:
 
1,5 - 120 sqmm dipasok di drum kayu @ 1000 meter
150 - 300 sqmm tersedia dalam drum kayu dengan panjang yang tersedia
Panjang Toleransi per drum ± 2% (I)

Cu/XLPE/DSTA/PVC 0.6/1 (1.2) kV (N2XBY)

Versi ramah cetakPDF version
 
 
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Inner Sheathed, Double Steel Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502 – 2
 
Application :
For installation indoor, in ground direct burried, for power station and switchgear, if there is a risk that low mechanical damage may occur.
 
Special Features on Request :
 
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Note : Conductor Shape
35 – 300 sqmm supplied in compacted circular stranded (cm) conductor shape
 
Standard Packing :
 
35 – 70 sqmm supplied in wooden drum @ 1000 meters
95 – 300 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%
 

T-ACSR

Versi ramah cetakPDF version
Material Inti: 
Al

Sertifikasi SNI

Bahasa Indonesia

OHSAS 18001: 2007 Health and Safety

English
The OHSAS 18000 standard provides elements of an effective safety management system that can be integrated with other management systems and helps organizations achieve better health and safety performance and economic goals.
 
BS OHSAS 18001 establishes requirements for OHS management systems to help organizations develop and implement policies and objectives, which take into account legal and information requirements about OHS risk. It applies to all types and sizes of the organization and accommodates a wide range of geographic, cultural and social conditions.
 
BS OHSAS 18002 provides guidance for establishing, implementing or improving management systems based on OHSAS 18001 and demonstrating the successful application of OHSAS 18001.
 
OHSAS 18001 can be adjusted to the existing ISO 9001 and ISO 14001 management systems. Historically many organizations started with the ISO 9001 quality management system, then added the environmental management requirements of ISO 14001. Many organizations now see the implementation of these three standards at once that can minimize costs and disruptions. Standards can be integrated using standards such as BSI PAS 99.
OHSAS 18001: 2007 Health - Safety certificate
 
Valid: November 28, 2017 to November 11, 2020
 
PLEASE DOWNLOAD THE CERTIFICATION PROOF
 

Selamat Datang di Prima Cable Indo

Versi ramah cetakPDF version

PT.  Prima Cable Indo berdiri sejak tahun 2002 dan bergerak di bidang usaha kabel manufacturing dengan memproduksi berbagai macam jenis kondutor transmisi dan distribusi, building wire, control cable, telecomunication cable, etc

 

Kantor berlokasi di daerah Jakarta Pusat serta memiliki 2 lokasi pabrik di Tangerang dan Bandung.  PT. Prima Cable Indo memproduksi 2 merk kabel yakni PUTERA  CABLE Kabel dan PRICA CABLE
 

ISO 9001:2015 Standar Manajemen Mutu

Versi ramah cetakPDF version

ISO 9001 adalah standar untuk sistem manajemen mutu, mengacu kepada beberpa standard manajemen yang telah didapat 
PT Prima Cable Indo telah mendapatkan sertifikat ISO 9001:2015 yang merupakan sebagai bentuk pertanggung jawab terhadap standar-standar sistem manajemen mutu 
 
 

ISO 14001:2015 Environment Management

Versi ramah cetakPDF version

ISO 14000 is a set of environmental management standards developed to assist organizations to:

 

    minimize the negative impacts of their activities (processes etc) on the environment, such as causing adverse changes to air, water or land;

    comply with applicable law and enforceable environmental laws and regulations;

    fix things above on an ongoing basis.

 

ISO 14000 is similar to ISO 9000 - quality management in terms of how a product is produced rather than about the product itself. As with ISO 9000, the certification is performed by a third party, not by the ISO itself. ISO 19001 audit standard is applied when auditing ISO 9000 and 14000 compliance at once.

 

The requirements of ISO 140001 are an integral part of the EU's Eco-Management and Audit Scheme (EMAS), which is more demanding, especially regarding upgrading tasks, legal compliance and performance reporting.
Certificatet ISO 14001:2015 Environment Management

 
Valid : 28 November 2017 s/d 11 November 2020

BCC-SOFT

Versi ramah cetakPDF version
Material Inti: 
Cu

About  BCC

Cable Bare Copper Conductor (BCC) is a bare Copper Wire that is usually used for air ducts and ground cables.

 

Features

This type of BCC conductor is used for air channel power transmission.

 

Construction

Conductors: Seven copper or more wires of the same diameter in concentric layers.

 

Bare Copper Conductor - Hard (BCC-H)

Conductors having mechanical characteristics of at least 428 N / mm2. Maximum resistivity at 20 degrees Celsius is 0.01786 ohm.mm2 / m

 

Bare Copper Conductor - Half Hard (BCC-1 / 2H)

Conductors having minimal mechanical characteristics of 340 N / mm2. Maximum 410 N / mm2. Maximum resistivity at 20 degrees Celsius is 0.01784 ohm.mm2 / m

 

Annealed Copper Wire (BCC Soft)

This conductor has a maximum resistivity at 20 degrees Celsius is 0.017241 ohm.mm2 / m

 

Type:

BCC-1 / 2H

BCC-Soft

 

Specification

SPLN 41-4: 1981

SPLN 41-5: 1981

JIS C 3102

(Other specifications are also available on request)

 

Here for example BCC cable 120 mm2

Cu/PVC/DSTA/PVC 0.6/1 (1.2) kV (NYBY)

Versi ramah cetakPDF version
Material Inti: 
Cu
0.6/1 kV, NYBY (Cu / PVC / DSTA / PVC)
(Copper Conductor, PVC Insulated, Double Steel Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502 – 1
 
Application :
For installation indoors, cable channels and in ground, for industry installations, switchgear, and power station, if there is a risk that low mechanical damage may occur.
 
Special Features on Request :
 
Fire Resistance
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Anti Rodent
Low Smoke Zero Halogen
Note: Conductor shape
 
1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 – 300 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape
Standard Packing :
 
1.5 – 120 sqmm supplied in wooden drum @ 1000 meters
150 – 300 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%

Cu/XLPE/DSTA/PVC 0.6/1 (1.2) kV (N2XBY)

Versi ramah cetakPDF version
Material Inti: 
Cu
Cu/XLPE/DSTA/PVC
 
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Inner Sheathed, Double Steel Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502 – 2
 
Application :
For installation indoor, in ground direct burried, for power station and switchgear, if there is a risk that low mechanical damage may occur.
 
Special Features on Request :
 
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Note : Conductor Shape
35 – 300 sqmm supplied in compacted circular stranded (cm) conductor shape
 
Standard Packing :
 
35 – 70 sqmm supplied in wooden drum @ 1000 meters
95 – 300 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%
 

T-ACSR/AS

Versi ramah cetakPDF version
Material Inti: 
Al

STANDAR TINGGI

Bahasa Indonesia

Prima Cable Indo memproduksi kabel dengan menggunakan kawat paduan tembaga berkekuatan tinggi yang dikembangkan secara independen. Sambil mempertahankan konduktivitas yang tinggi, kawat ini memiliki kekuatan tarik dan kekuatan lentur berulang dua kali lipat dari kawat paduan umum dan daya tahan lenturnya yang superior memastikan umur yang panjang. Prima Cable Indo mampu menyesuaikan proposal untuk robot industri, serta berbagai skenario di mana kabel fleksibel dibutuhkan.

SNI Certification

English

About Us

Versi ramah cetakPDF version
Prima Cable Indo is a company engaged in manufacturing Electric and Telecommunication Cables built in 1994. The company formerly known as Putra Ometraco Elektrik has become one of the cable manufacturers with high technology and quality.
 
Our products include low-and medium-voltage power cables, telecommunication cables all of which are designed according to national and international standards such as JIS, VDE, SPLN (LMK) .rima Cable Indo has headquarters in Jakarta with operational facilities at Jatiuwung Industrial Zone, Tangerang Banten - Indonesia.
 
Currently Prima Cable Indo has had consumers both from home and abroad. Prima Cable Indo continues to invest for new machines as well as human resources to develop production capacity and quality. We always use the best materials and cutting-edge technology to maximize cable performance and maintain the specification standards of each cable according to function.
 

ISO 14001:2015 Manajemen Lingkungan

Versi ramah cetakPDF version

ISO 14001 mendefinisikan kriteria untuk manajemen lingkungan.  Dengan sertifikasi ISO 14001 dapat memberikan kepastian kepada manajemen perusahaan dan karyawan serta pemangku kepentingan eksternal bahwa dampak lingkungan dapat diukur dan dikendalikan. ISO 14001 juga dapat diintegrasikan dengan fungsi manajemen lainnya dan membantu perusahaan dalam memenuhi tujuan peningkatan lingkungan dan ekonomi mereka. PT. Prima Cable Indo telah memiliki sertifikat  ISO 14001:2015 

CUSTOMER SATISFACTION

Versi ramah cetakPDF version

PT. Prima Cable Indo, ensures customer satisfaction by applying ISO 9001: 2015 standard in producing cables for its customers

Konten Page Layout Test

Versi ramah cetakPDF version

Menteri Pendayagunaan Aparatur Negara dan Reformasi Birokrasi (Menpan RB) Asman Abnur mengatakan kementerian saat ini sedang melakukan perbaikan sistem dalam merekrut pegawai yang menjadi PNS terutama secara langsung baik dari sekolah negeri maupun swasta.
Menurutnya selama ini ada kekurangan dalam proses pencarian pegawai. Dengan sistem komputerisasi, diharapkan membuat tahapan seleksi PNS menjadi tidak mudah. “Sekarang proses seleksi dilakukan dengan sistem terbuka,” katanya, Sabtu (27/1/2018).

Unduhan : 
PDF icon public-11.pdf (161.76 KB)

Training Penarikan Absen

PRODUK

Versi ramah cetakPDF version

Tentang Produk

Cu/PVC/PVC 450 / 750 V (NYM)

Versi ramah cetakPDF version
Material Inti: 
Cu
CU / PVC / PVC (NYM)
Konduktor Tembaga, Insulated PVC, PVC Sheathed
 
KAWAT PENAMPANG
450/750 V
 
Spesifikasi Standar:
SPLN 42 -2: 1992
SNI 6629.4: 2006
 
Aplikasi:
Pemasangan permanen di saluran
Atau Kabel yang terkena di lokasi kering
 
Konduktor Bentuk:
1,5 - 10 sqmm disuplai solid (re) atau circular stranded (rm)
16 - 400 sqmm disertakan dalam sirkuler terdampar (rm)
 
Packing Standar:
1,5 - 10 sqmm sistem Coil
Drum kayu 16 - 400 sqmm
 
Fitur Khusus pada Permintaan
 
Unduhan : 
PDF icon NYM.v1.pdf (517.86 KB)

Cu/XLPE/CTS/PVC 0.6/1 (1.2) kV (N2XSY)

Versi ramah cetakPDF version
Material Inti: 
Cu
N2XSY ( Cu / XLPE / CTS / PVC )
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed)
Standard Specification : IEC 60502 – 2
 
 
Application :
Indoors, cable trunking, outdoors and in ground; For power stations, industry and switchgear.
 
Special Features on Request :
 
Oil Resistance
UV Resistance
Flame Retardant Cat. A, B, C
Flame Retardant Non Category
Heat Resistance
Anti Termite
Note : Conductor Shape
35 – 300 sqmm supplied in compacted circular stranded (cm) conductor shape
 
Standard Packing :
 
35 – 95 sqmm supplied in wooden drum @ 1000 meters
120 – 300 sqmm supplied in wooden drum on available length
Length Tolerance per drum ± 2%

GSW

Versi ramah cetakPDF version
Detil Deskripsi produk
Konduktor: Galvanized Steel Wire nama sandi: GSW
Tunggal kawat Diameter: 1,24-2,50 Kekuatan tarik: 1290mpa ~ 1620mpa
Aplikasi: Inti dari ACSR
 

 

Galvanized Steel Wire Bare Conductor

 

 

Kawat produk baja galvanis (GSW) digunakan untuk kabel dari ACSR (Aluminium Conductor Steel Reinforced) konduktor

 

Tentang Kami

Bahasa Indonesia

Prima Cable Indo adalah perusahaan yang bergerak dibidang manufaktur Kabel Listrik dan Telekomunikasi yang dibangun pada tahun 1994. Perusahaan yang dulu bernama Putra Ometraco Elektrik ini telah menjadi salah satu produsen kabel dengan teknologi dan kualitas yang tinggi. Produk kami meliputi kabel listrik bervoltase rendah dan menengah, kabel telekomunikasi yang semuanya di desain sesuai standar nasional maupun internasional seperti JIS, VDE, SPLN (LMK).rima Cable Indo memiliki kantor pusat di Jakarta dengan fasilitas operasional di Zona Industri Jatiuwung, Tangerang Banten - Indonesia.

Saat ini Prima Cable Indo telah memiliki konsumen baik dari dalam dan luar negeri. Prima Cable Indo terus berinvestasi untuk mesin-mesin baru dan juga sumber daya manusia untuk mengembangkan kapasitas dan kualitas produksi. Kami selalu menggunakan bahan-bahan terbaik dan berteknologi mutakhir untuk memaksimalkan performa kabel dan menjaga standar spesifikasi tiap kabel sesuai fungsinya.
Prima Cable Indo selalu membuat produk yang terbaik. Karena kami adalah sumber berpengalaman untuk segala jenis macam kebutuhan kabel.

ISO 9001: 2015 Quality Management Standards

English
ISO 9001: 2015 Quality Management
 
ISO 9000 is a set of standards for quality management systems (QMS). ISO 9000 formulated by TC 176 ISO, the international organization in the field of standardization. ISO 9000 was first issued in 1987 by the International Organization for Standardization Technical Committee (ISO / TC) 176. [1] ISO / TC is responsible for the standards of the quality management system. [1] ISO / TC 176 establishes a review cycle every five years, to ensure that ISO 9000 standards will be up to date and relevant to the organization. [1] Revisions to ISO 9000 standards have been made in 1994 and 2000. [1]
    the existence of a set of procedures covering all important processes in the business;
    supervision in the manufacturing process to ensure that the system produces quality products;
    keeping important data and archives well;
    inspection of goods that have been produced to locate the damaged units, with correct corrective action if necessary;
    regularly review the effectiveness of each process and the quality system itself.
Valid: 29 November 2017 to 14 December 2018
Jl. Kesehatan Raya no. 18 - 20 Petojo Selatan, Gambir
10160 Jakarta Pusat , JK
Indonesia
Phone: +62 21 3510642
Fax: +62 21 3517027
Jl. Kawasan Industri Keroncong Kp. Gebang Raya Kelurahan Gebang Raya Kecamatan Priuk Tangerang
15132 Kota Tangerang , BT
Indonesia
Phone: + 62 21 5901453, 59309179
Fax: + 62 21 5901455
Jl. Raya Sapan No 100 Desa Tegalluar Bojongsoang
40297 Bandung , JR
Indonesia
Phone: +62 22 87528467
Fax: +62 22 87528468

Situs

Primacableindo © 2018